Arq. bras. oftalmol ; 86(5): e20230070, 2023. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1513677

ABSTRACT

ABSTRACT Purpose: Postoperative refraction in modern mi­croincision cataract surgery gained extra importance in patients with the previous laser-assisted in situ keratomileusis (LASIK) surgery. The surgically induced astigmatic changes in those eyes may differ not only in magnitude but also in direction compared to virgin corneas. This study aimed to compare the surgically induced astigmatic changes after microscopic cataract surgery between post-LASIK corneas and virgin eyes. Methods: Cases that underwent microincision cataract surgery in eyes with and without previous LASIK surgery were reviewed. The demographics, the axial length at cataract surgery, the central corneal thickness, spheric and cylindric values, keratometry readings, and postoperative posterior corneal astigmatism were retrospectively evaluated. A modified Alpins method was used for astigmatic vector analysis, and baseline astigmatism, surgically induced astigmatism, difference vector, flattening effect, and torque were assessed. Results: A total of 42 eyes from 24 subjects was evaluated. Group I consisted of 14 eyes with the previous LASIK, and Group II included 28 eyes without any refractive surgery. Preoperative mean central corneal thickness in Group I was significantly thinner (p=0.012). There was no significant difference in baseline astigmatism between the groups regarding magnitude and power vectors. After microincision cataract surgery, there were no significant differences in mean spheric and cylindric values and mean keratometry readings (all p>0.05). However, surgically induced astigmatism and difference vector were significantly higher on J45 vector component in post-LASIK eyes and microincision cataract surgery steepening effect on post-LASIK corneas was significantly higher than those in virgin eyes (p=0.001, p=0.002 and p=0.018, respectively). Conclusions: Cataract surgery has steepened the corneas in both groups with a significantly higher steepening effect in post-LASIK eyes. Certainly, corneal topography cataract surgery is particularly helpful to provide more precise surgically induced astigmatism interpretations.


RESUMO Objetivo: A refração pós-operatória na cirurgia mo­derna de catarata por microincisão ganha ainda mais importância em pacientes com cirurgia prévia de ceratomileuse in situ assistida por laser (LASIK). As alterações astigmáticas induzidas cirurgicamente nesses olhos podem diferir não apenas em magnitude, mas também em direção em comparação com córneas virgens. O objetivo deste estudo foi comparar as alterações astigmáticas induzidas cirurgicamente após cirurgia de catarata por microincisão entre córneas pós-LASIK e olhos virgens. Métodos: Foi revisada uma série de casos de cirurgia de catarata por microincisão em olhos com e sem cirurgia LASIK anterior. Os dados demográficos, o comprimento axial no momento da cirurgia de catarata, a espessura central da córnea, os valores esféricos e cilíndricos, as leituras da ceratometria e o astigmatismo corneano posterior pós-operatório foram avaliados retrospectivamente. O método Alpins modificado foi usado para análise vetorial astigmática e foram avaliados o astigmatismo basal, o astigmatismo induzido cirurgicamente, o vetor de diferença, o efeito de achatamento e o torque. Resultados: Ao todo, 42 olhos de 24 indivíduos foram avaliados. O Grupo I consistiu em 14 olhos com LASIK prévio; o Grupo II incluiu 28 olhos sem qualquer cirurgia refrativa. A média da espessura corneana central pré-operatória no Grupo I foi significativamente mais fina (p=0,012). Não houve diferença significativa no astigmatismo basal entre os grupos em termos de magnitude e vetores de potência. Após a cirurgia de catarata por microincisão, não houve diferenças significativas nos valores médios esféricos, cilíndricos e leituras médias de ceratometria (todos com p>0,05). No entanto, o astigmatismo induzido cirurgicamente e o vetor de diferença foram significativamente maiores no componente do vetor J45 em olhos pós-LASIK, e o efeito de aumento da inclinação pela cirurgia de catarata por microincisão nas córneas pós-LASIK foi significativo em comparação com olhos virgens (p=0,001, p=0,002 e p=0,018, respectivamente). Conclusões: A cirurgia de catarata aumentou a inclinação das córneas em ambos os grupos, sendo esse aumento significativamente maior nos olhos pós-LASIK. Certamente, a topografia da córnea antes da cirurgia de catarata é particularmente útil para fornecer interpretações mais precisas do astigmatismo induzido cirurgicamente.

2.
Rev. bras. oftalmol ; 82: e0021, 2023. graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1441325

ABSTRACT

RESUMO O FemtoLasik é uma das técnicas mais empregadas em cirurgia refrativa, por seus bons resultados refracionais, sua previsibilidade, sua reprodutibilidade e sua segurança. Tem alto grau de satisfação, com rápida recuperação visual. Apesar de as taxas de complicações do FemtoLasik serem pequenas, intercorrências podem existir. O objetivo deste trabalho foi relatar um caso de uma complicação na dissecção da lamela por Lasik com laser de femtossegundo com consequente rasgadura da lamela, sendo aplicado Excimer Laser com mitomicina C 0,02%. O retratamento foi realizado com ablação de superfície (ceratectomia fotorrefrativa) guiada por frente de onda, evoluindo com boa qualidade visual final.


ABSTRACT Femtolasik is one of the most used techniques in refractive surgery due to good refractive results, predictability, reproducibility, and safety, achieving excellent results and a high degree of satisfaction. Although the complication rates are small, it is worth noting that there may be intercurrences. The objective of this work is to report a case of complication in the dissection of the lamella of laser in situ keratomileusis (Lasik) with Femtosecond laser, and subsequent lamella tear. Excimer Laser was applied with mitomycin 0.02% and re-approached with wavefront guided surgery, evolving with good final visual quality.

3.
Rev. bras. oftalmol ; 80(1): 67-70, jan.-fev. 2021. graf
Article in Portuguese | LILACS | ID: biblio-1251316

ABSTRACT

RESUMO O laser in situ keratomileusis (LASIK) é o método cirúrgico refrativo mais realizado no mundo com excelentes resultados, porém tal método não é isento de riscos. A ectasia pós LASIK é uma complicação grave e se caracteriza por um aumento progressivo da curvatura e afinamento da córnea, resultando em astigmatismo irregular e diminuição da acuidade visual. Sua incidência na literatura atual é de aproximadamente 0,033%. O principal tratamento dessa complicação é o implante de anel intra-estromal com cross-linking. Neste artigo descrevemos um caso de uma mulher de 45 anos submetida a sucessivas tentativas de tratamento de ectasia pós LASIK, com implante de anel intra-estromal bilateral, sem sucesso em um dos olhos. Foi feito o uso do excimer laser topoguiado através do photorefractive keratectomy (PRK) sem o cross-linking, que optamos por não realizar pela estabilidade há anos, pelo risco alto de haze e pela ablação apenas na lamela (que era espessa).A paciente obteve melhorasignificativa da visão e da qualidade de vida. Mantemos o acompanhamento a cada seis meses desde então com a tomografia da córnea.


ABSTRACT The laser in situ keratomileusis (LASIK) is the most widely used refractory surgical method in the world with excellent results, but this method is not without risks. Post-LASIK ectasia is a serious complication and is characterized by a progressive increase in curvature and thinning of the cornea, resulting in irregular astigmatism and decreasing visual acuity. Its incidence in the current literature is approximately 0.033%. The main treatment for this complication is the implantation of an intra-stromal ring with crosslinking. In this article, we describe a case of a 45-year-old woman who underwent successive attempts to treat post-LASIK ectasia, with bilateral intra-stromal ring implantation, with no success in the eyes. Excimer laser was used, made through photorefractive keratectomy (PRK) without cross-linking and the patient obtained significant improvement in vision and in quality of life.


Subject(s)
Humans , Female , Middle Aged , Photorefractive Keratectomy/methods , Keratomileusis, Laser In Situ/adverse effects , Tomography, Optical Coherence/methods , Dilatation, Pathologic/etiology
4.
Rev. bras. oftalmol ; 80(3): e0012, 2021. tab, graf
Article in Portuguese | LILACS | ID: biblio-1280123

ABSTRACT

RESUMO O implante de lentes intraoculares fácicas com finalidade refrativa é uma alternativa cirúrgica eletiva segura e eficiente. Essa opção deve ser considerada de forma eletiva para tratar ametropias, nos casos em que as cirurgias de correção visual refrativa a laser na córnea apresentam maior risco de complicações, seja por características da córnea ou pela magnitude da ametropia. Este artigo traz uma revisão prospectiva das lentes fácicas disponíveis no mercado brasileiro em 2020 e suas características.


ABSTRACT Implantation of phakic intraocular lenses for refractive purpose is a safe and efficient elective surgical alternative. This option should be considered to electively treat ametropia when laser corneal refractive surgery has higher risk of complications, either due to corneal characteristics or the magnitude of ametropia. This article provides a prospective review of the phakic lenses available in the Brazilian market in 2020 and their characteristics.


Subject(s)
Astigmatism/surgery , Refractive Surgical Procedures , Phakic Intraocular Lenses , Myopia/surgery
5.
Rev. bras. oftalmol ; 79(5): 344-347, set.-out. 2020. graf
Article in Portuguese | LILACS | ID: biblio-1137992

ABSTRACT

Resumo A cirurgia de catarata com implante de lente intra-ocular é uma das cirurgias mais realizadas no mundo e, atualmente, os pacientes que se submetem a essa cirurgia podem utilizar o implante com lente intraocular (LIO) multifocal como alternativa ao uso de óculos. Um grande desafio para o cirurgião são os pacientes já submetidos previamente a ceratotomia radial (RK), pois além de terem um cálculo biométrico mais desafiador, apresentam importantes aberrações ópticas corneanas, sendo uma contra-indicação para o uso de lentes multifocais para a maioria dos oftalmologistas. Neste artigo, relatamos o caso de uma paciente que foi submetida, na juventude, a uma RK e passou a referir importante incômodo visual após a correção de catarata com facectomia e implante de LIO multifocal. Esta paciente foi submetida a uma ceratectomia fotorrefrativa (PRK) para diminuir as irregularidades da córnea com boa evolução clínica e resultado visual satisfatório. Esse caso chama a atenção para a alternativa do excimer laser topoguiado em casos semelhantes e alerta para o risco do uso desse tipo de lente em córneas irregulares.


Abstract Cataract surgery with intraocular lens implantation is one of the most commonly performed surgeries in the world and, currently, patients who undergo this surgery can use the multifocal intraocular lens (IOL) implant as an alternative to wearing glasses. A great challenge for the surgeon are patients who have previously undergone radial keratotomy (RK), because in addition to having a more challenging biometric calculation, they also have important corneal optical aberrations, being a contraindication for the use of multifocal lenses for most patients. ophthalmologists. In this article, we report the case of a patient who underwent a RK in her youth and started to report an important visual discomfort after cataract correction with facectomy and multifocal IOL implantation. This patient underwent a photorefractive keratectomy (PRK) to reduce corneal irregularities with good clinical evolution and satisfactory visual result. This case draws attention to the alternative of topography-guided laser excimer in similar cases and warns of the risk of using this type of lens in irregular corneas.


Subject(s)
Humans , Female , Middle Aged , Keratotomy, Radial , Eye Abnormalities/surgery , Photorefractive Keratectomy , Refractive Surgical Procedures , Lasers, Excimer/therapeutic use , Multifocal Intraocular Lenses
6.
Rev. bras. oftalmol ; 75(2): 160-165, Mar.-Apr. 2016. tab, graf
Article in Portuguese | LILACS | ID: lil-779966

ABSTRACT

RESUMO Este artigo apresenta uma revisão dos princípios e das aplicações clínicas do princípio de Scheimpflug na área da imagiologia do segmento anterior. Ao disponibilizar uma imagem tridimensional do segmento anterior, esta tecnologia permite a caraterização da elevação e curvatura das superfícies anterior e posterior da córnea, o mapeamento paquimétrico, o cálculo do poder refrativo total da córnea e a biometria do segmento anterior. Na subespecialidade de cirurgia refrativa, esta abordagem melhora a capacidade de identificação de casos com risco de desenvolver ectasia, bem como de planeamento e de avaliação dos resultados dos procedimentos cirúrgicos. Recentemente, esta tecnologia foi introduzida na avaliação biomecânica in vivo da córnea e na cirurgia de catarata assistida por laser de femtossegundo.


ABSTRACT This article presents a review of the principles and clinical applications of the Scheimpflug principle in the anterior segment imaging. By providing a three-dimensional image of the anterior segment, this technology provides elevation and curvature data of the anterior and posterior surfaces of the cornea, pachymetric mapping, the total refractive power of the cornea and the anterior segment biometry. For the refractive surgery sub-specialty, this approach improves the ability to identify cases at risk of ectasia, as well as the planning and evaluation of the results of surgical procedures. Recently, this technology was introduced in corneal biomechanical in vivo evaluations and in femtosecond laser-assisted cataract surgery.


Subject(s)
Humans , Ophthalmology/instrumentation , Biomechanical Phenomena , Photography/methods , Cornea/anatomy & histology , Anterior Eye Segment/anatomy & histology , Tonometry, Ocular , Algorithms , Image Processing, Computer-Assisted , Data Display , Photography/instrumentation , Photography/standards , Tomography/methods , ROC Curve , Biometry/instrumentation , Cornea/pathology , Cornea/diagnostic imaging , Corneal Topography/methods , Imaging, Three-Dimensional , Diagnostic Techniques, Ophthalmological , Anterior Eye Segment/pathology , Anterior Eye Segment/diagnostic imaging
7.
Arq. bras. oftalmol ; 76(5): 270-273, set.-out. 2013. ilus
Article in English | LILACS | ID: lil-690602

ABSTRACT

PURPOSE: The present study aimed to compare the postoperative contrast sensitivity functions between wavefront-guided LASIK eyes and their contralateral wavefront-guided PRK eyes. METHODS: The participants were 11 healthy subjects (mean age=32.4 ± 6.2 years) who had myopic astigmatism. The spatial contrast sensitivity functions were measured before and three times after the surgery. Psycho and a Cambridge graphic board (VSG 2/4) were used to measure luminance, red-green, and blue-yellow spatial contrast sensitivity functions (from 0.85 to 13.1 cycles/degree). Longitudinal analysis and comparison between surgeries were performed. RESULTS: There was no significant contrast sensitivity change during the one-year follow-up measurements neither for LASIK nor for PRK eyes. The comparison between procedures showed no differences at 12 months postoperative. CONCLUSIONS: The present data showed similar contrast sensitivities during one-year follow-up of wave-front guided refractive surgeries. Moreover, one year postoperative data showed no differences in the effects of either wavefront-guided LASIK or wavefront-guided PRK on the luminance and chromatic spatial contrast sensitivity functions.


OBJETIVO: A proposta do presente estudo é comparar funções de sensibilidade ao contraste obtidas após wavefront-LASIK e wavefront-PRK no olho contralateral. MÉTODOS: Os participantes foram 11 sujeitos saudáveis (idade média=32,4 ± 6,2 anos) com astigmatismo miópico. As funções de sensibilidade ao contraste espacial foram obtidas antes e três vezes após a cirurgia. O programa Psycho e uma placa gráfica da Cambridge Research Systems (VSG 2/4) permitiram gerar os estímulos com contraste espacial de luminância e cromático (verde-vermelho e azul-amarelo) de 0,85 até 13,1 ciclos/grau. Análises longitudinais e comparações entre as cirurgias foram realizadas. RESULTADOS: Não houve mudança significativa da sensibilidade ao contraste durante o primeiro ano após a cirurgia para o olho que recebeu o LASIK ou para o olho que recebeu o PRK. A comparação entre as cirurgias também foi semelhante no pós-operatório de um ano. CONCLUSÕES: Os resultados apresentados mostraram sensibilidade ao contraste semelhante durante o primeiro ano após a cirurgia refrativa com o wavefront. Além disso, no pós-operatório de um ano não houve diferença nas funções de sensibilidade ao contraste de luminância e cromático entre os olhos que receberam LASIK e os que receberam PRK.


Subject(s)
Adult , Female , Humans , Male , Astigmatism/surgery , Contrast Sensitivity/physiology , Keratomileusis, Laser In Situ/methods , Myopia/surgery , Photorefractive Keratectomy/methods , Light , Prospective Studies , Refractive Surgical Procedures/methods , Treatment Outcome
8.
São Paulo; s.n; 2011. [90] p. tab, ilus.
Thesis in Portuguese | LILACS | ID: lil-609408

ABSTRACT

Objetivo: Investigar as alterações biomecânicas da córnea de suínos induzidas pela confecção de lamelas pediculadas de diferentes espessuras pelo laser de femtossegundo. Métodos: Para a formação dos dois grupos, 12 olhos de porcos foram usados: lamelas pediculadas de 100 e de 300 micrômetros confeccionadas pelo laser de femtossegundo. Cada olho foi submetido aos seguintes exames, antes da criação das lamelas: topografia por rasterstereography, Ocular Response Analyzer (ORA), tomografia do segmento anterior por coerência óptica para a avaliação paquimétrica corneal e das lamelas criadas e sistema de velocidade de onda (SVO), que mede a velocidade de propagação de ondas acústicas entre dois transdutores posicionados na superfície corneal antes e imediatamente, após a feitura da lamela. O primerio passo foi desenhado para o estudo das diferenças em relação à histerese corneal, fator de resistência corneal, mudanças na curvatura e velocidade de propagação de onda acústica entre córneas com lamelas finas e espessas. Posteriormente, as lamelas foram amputadas, e as medidas do sistema de velocidade de onda foram repetidas. Resultados: A média de espessura das lamelas ± desviopadrão (DP) foi de 108,5±6,9 (8,5% da espessura total) e 307,8±11,5 m (22,9% da espessura total), para os grupos de lamelas finas e espessas, respectivamente (p< 0,001). Histerese corneal e o fator de resistência corneal não apresentaram diferença estatística, após a criação de lamelas finas (p = 0,81 e p = 0,62, respectivamente). Histerese corneal foi significantemente mais baixa, depois da confecção de lamelas mais espessas (8,0±1,0 para 5,1±1,5 mmHg para medidas pré e pós-operatórias, respectivamente, p = 0,003, diminuição de 36,25%) e fator de resistência corneal também mostrou significante diminuição nesse grupo, após o procedimento cirúrgico; valores médios pré e pós-operatórios de...


Purpose: To study the impact of programmed flaps at two different thicknesses on the biomechanical properties of the swine corneas. Methods: Twelve pig eyes were enrolled in this study and were formed two groups: 100m and 300 m flaps performed with the femtosecond laser. Each eye had the following procedure before the flap creation: raster photograph topographic maps, Ocular Response Analyzer (ORA), Optical Coherence Tomography to measure the pachymetry and flap thickness and Surface Wave Velocity system which is a prototype system that measures sonic wave propagation time between two transducers positioned on the corneal surface before and after flap creation. This first step was designed to investigate the differences in respect to corneal hysteresis, corneal resistance factor, curvature change and ultrasonic wave propagation between the groups with thinner and thicker flaps. After this initial procedure, flap amputation was performed and new measurements with the surface wave velocity system were taken again. Results: Measured flap thicknesses averaged 108.5±6.9 (8.5% of the total cornea) and 307.8±11.5 m (22.9% of the total cornea) for thin and thick flap groups, respectively (p< 0.001). Hysteresis and corneal resistance factor did not change significantly after flap creation in the thin flap group (p = 0.81 and p = 0.62, respectively). With thicker flaps, both parameters decreased significantly from 8.0±1.0 to 5.1±1.5 mmHg (p=0.003, reduction of 36.25%) and from 8.2±1.6 to 4.1±2.5 mmHg, respectively (p = 0.007), reduction of 50%. Simulated keratometry values increased in the thick flap group (from 39.5±1 D to 45.9±1.2 D, p=0.003) after flap creation and not in the thin flap group (from 40.6±0.6D to 41.4±1.0D, p= 0.55). Regarding surface wave velocity analysis, the surgical procedures induced lower values in some positions although most of them did not present statistically different results. Conclusion: In this experimental model, thicker flaps...


Subject(s)
Animals , Biomechanical Phenomena , Cornea , Corneal Topography , Dilatation, Pathologic , Keratomileusis, Laser In Situ , Swine
9.
Investig. andin ; 11(19)sept. 2009.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1534689

ABSTRACT

Introducción: detectar la ocurrencia de Aniseikonia Meridional Horizontal en pacientes operados de cirugía refractiva por el sistema LASIK. Métodos: una muestra de 19 pacientes emetropizados por LASIK es comparada con una muestra de 20 pacientes naturalmente emétropes, con el objeto de estimar el efecto que los cambios de curvatura corneal tienen sobre el meridiano horizontal de la imagen retinal, teniendo en cuenta que las variaciones del poder óptico del ojo altera la posición del Punto Nodal, lo que a su vez altera el tamaño de la imagen retinal. Las ametropías preexistentes no fueron tomadas en cuenta. Para el estudio fue utilizado el Test Monocular de Merchán para detectar Aniseikonia (Merchán G. 2004): un elipsoide generado por computador incrementa su meridiano horizontal, contra orden dada, acercándose así a la figura de un círculo perfecto. El paciente activa el test y es instruido para detenerlo cuando considere que el elipsoide ha adquirido la forma de un círculo perfecto. En este momento el software compara los ejes horizontal y vertical de la figura resultante y muestra en porcentaje cualquier diferencia entre ellos; lo ideal es que el eje horizontal sea 100% igual al vertical, lo cual significa que la figura es realmente un círculo y así es percibido por el paciente, probando además que en el ojo examinado no existe ninguna Magnificación Meridional Horizontal. El ojo compañero es ahora sometido a la misma prueba y los resultados de los dos son comparados. Una diferencia entre ellos del 3% o superior (Borish, 1975) es considerada indicadora de Aniseikonia Meridional Horizontal. Resultados: los análisis estadísticos de proporciones, Z, tanto de una cola como de dos para el valor Z de diferencia entre proporciones, 36.8% de la primera muestra (emétropes por LASIK) y 5% de la segunda (naturalmente emétropes) es significativa, por lo cual se rechaza la hipótesis nula en favor de la alternativa. Conclusiones: la cirugía refractiva altera la curvatura corneal y consecuentemente la posición del Punto Nodal, lo cual puede causar una Aniseikonia Meridional Horizontal de grado bajo y asintomática aproximadamente en la tercera parte de los casos examinados.


Introduction: to detect the occurrence of Horizontal Meridional Aniseikonia in patients operated of refractive surgery with LASIK. Methods and materials: a sample of 19 patients made emmetropic by LASIK intervention is compared t a sample of 20 naturally emmetropic patients in order to asses the effect that changes in corneal curvature have over the horizontal meridian of the retinal image taking into account that variations of the optical power of the eye alters the position of the Nodal Point which in turn alters the size of the retinal image. Pre-existing ametropia was not specified or taken into account. Merchan Monocular Test for Aniseikonia was used for this study (Merchán G. 2004). A computer generated vertically elongated ellipsoid increases, upon command, the horizontal axis gradually approaching a perfect circle. The patient activates the test and is asked to stop the moment he or she considers that the ellipsoid has turned into a perfect circle. At this point the software compares the horizontal to the vertical axis of the resulting figure. Any difference between the axes is shown in percentage. Ideally, the horizontal axis should be 100% equal to the vertical axis which means that the figure is really a circle and is perceived as such by the patient, furthermore proving that no Horizontal Meridional Magnification is present in the eye under testing. The fellow eye is similarly tested and the results of the two eyes are compared. Differences above 3% (Borish, 1975) is considered indicative of the presence of Horizontal Meridional Aniseikonia. Results: statistical analyses for both one-tail and two-tails for the Z value for difference in proportions of the two groups show that 36.8% in the first group (emétropes by surgery) is statiscally significant from 5% in the second group (natural emmetropes), thus rejecting the null hypotheses. Conclusions:refractive surgery changes the corneal curvature and consequently the position of the Nodal Point all of which may cause a secondary asymptomatic low degree Horizontal Meridional Aniseikonia in approximately one third of the cases examined.


Objetivo: detectar a ocorrência de Aniseiconia Meridional Horizontal em pacientes operados de cirurgia refrativa pelo sistema LASIK. Métodos: uma amostra de 19 pacientes emetropes por LASIK é comparada a outra amostra de 20 pacientes naturalmente amétropes, com o objetivo de estimar o efeito que as mudanças de curvatura da córnea tem sobre o meridiano horizontal da imagem da retina, tendo em conta que as variações do poder ótico do olho altera a posição do Ponto Nodal, que, por sua vez, altera o tamanho da imagem na retina. As ametropías preexistentes não foram levadas em consideração. Para o estudo foi utilizado o Teste Monocular de Merchán para detectar Aniseiconia (Merchán G. 2004) Um elipsoide gerado por computador incrementa seu meridiano horizontal, contra ordem dada, aproximando-se assim à figura de um círculo perfeito. O paciente ativa o teste e é instruído para detê-lo quando considere que o elipsóide adquiriu a forma de um círculo perfeito. Neste momento, o software compara os eixos horizontal e vertical da figura resultante e mostra em porcentagem qualquer diferença entre eles. O ideal é que o eixo horizontal seja 100% igual ao vertical, o que significa que a figura é realmente um círculo e assim é percebido pelo paciente, provando ademais, que no olho examinado não existe nenhuma Magnificação Meridional Horizontal. O olho companheiro é agora submetido à mesma prova e os resultados dos dois são comparados em seguida. Uma diferença entre eles de 3% ou superior (Borish, 1975) é considerada indicadora de Aniseiconia Meridional Horizontal. Resultados: as análises estatísticas de proporções, Z, tanto de uma fila como de duas para o valor Z de diferença entre proporções, 36,8% da primeira amostra (emétropes por LASIK) e 5% da segunda (naturalmente emértropes) é significativa pelo qual se rejeita a hipótese nula em favor da alternativa. Conclusão: a cirurgia refrativa altera a curvatura corneal e consequentemente, a posição do Ponto Nodal, pela qual pode causar uma Aniseiconia Meridional Horizontal de baixo grau e assintomática em aproximadamente a terceira parte dos casos examinados.

SELECTION OF CITATIONS